Claimed Specs
Beam
Flood,Spot
63° Air
Lumens
1800 High
Med
360 Low
Run Time (mins)
Charge Time
Weight
1230 grams
Claimed vs Actual Results
|
Lumens |
Beam Angle |
Runtime |
TLCI | CRI |
Claimed |
1800 |
60° |
|
97 |
|
Actual |
1453 |
63° |
|
81 |
|
Difference |
Beam Test
TLCI Graph
LUX Table Flood
Distance |
LUX |
Beam Diameter |
Field Diameter |
1m [3.28 ft] |
1060 |
1.23m |
1.43m |
3m [9.84 ft] |
127 |
3.68m |
4.28m |
6m [19.69 ft] |
36 |
1.23m |
1.43m |
LUX Table Spot
Distance |
LUX |
Beam Diameter |
Field Diameter |
1m [3.28 ft] |
9560 |
0.26m |
0.33m |
3m [9.84 ft] |
1550 |
0.79m |
1m |
6m [19.69 ft] |
453 |
0.26m |
0.33m |